Journal of Chemical and Pharmaceutical Research (ISSN : 0975-7384)

header
Reach Us reach to JOCPR whatsapp-JOCPR +44 1625708989
All submissions of the EM system will be redirected to Online Manuscript Submission System. Authors are requested to submit articles directly to Online Manuscript Submission System of respective journal.

Original Articles: 2010 Vol: 2 Issue: 3

UV-Spectrophotometric estimation of Diacerein in pharmaceutical formulation

Abstract

Three simple, precise and economical UV methods hav e been developed for the estimation of Diacerein in Pharmaceutical Formulations. Diacerein has the maximum absorbance at 256.2 nm in zero order spectra formed the basis for metho d A while first order derivative spectrum showed peak at 250.0 nm when n = 1 for method b and method C applied was Area under Curve (AUC) in wavelength range of 262.0-250.0 nm.. Metho d A utilises A1%, 1cm value at λ max for its analysis. Calibration curve (Regression equatio n) was used for method B and C for analysis of Diacerein respectively. Drug was found to obey t he Beer-Lambert’s law in the concentration range of 5-30μ g/mL in all three proposed methods. R esults of the analysis were validated statistically and by recovery studies. Results were found to be satisfactory and can be adopted for routine analysis of the drug