Original Articles: 2011 Vol: 3 Issue: 3
Spectrophotometric estimation of Blonanserin in pure drug and pharmaceutical formulation
Abstract
A simple, sensitive and accurate spectrophotometric method was developed in ultraviolet region for the estimation of blonanserin in pure drug and pharmaceutical formulation. Linear response obtained was in the concentration range of 2-10 μg/ml with correlation coefficient of 0.9999 in solvent. Excellent recovery proved that the method was sufficiently accurate. There is no interference from any common pharmaceutical additives and diluents. Results of the analysis were validated by recovery studies according to ICH Q2B guidelines.