Journal of Chemical and Pharmaceutical Research (ISSN : 0975-7384)

header
Reach Us reach to JOCPR whatsapp-JOCPR +44 1625708989
All submissions of the EM system will be redirected to Online Manuscript Submission System. Authors are requested to submit articles directly to Online Manuscript Submission System of respective journal.

Original Articles: 2013 Vol: 5 Issue: 11

Simultaneous estimation of levodopa and carbidopa in bulk, pharmaceutical dosage forms and dissolution sample analysis by RP-HPLC-PDA method

Abstract

A simple, specific, and accurate reverse phase liquid chromatographic method was developed for the simultaneous estimation of Levodopa (LD) and Carbidopa (CD) in bulk and pharmaceutical dosage forms. A Phenomenex C18- RP Aqueous reverse phase column (250 x 4.6mm, 5 μm) with mobile phase containing 0.05%(v/v) o-phosphoric acid: acetonitrile (96:4%v/v) was used at 1mL/min flow rate in isocratic mode and the eluents were monitored at 220 nm. The retention times of LD and CD were 4.2 and 7.4 min respectively and showed a good linearity in the concentration range of 20-100 μg/mL for LD and 10-50μg/mL for CD with a correlation coefficient (R) of 0.9999 and 0.9998. The percentage assays for controlled matrix tablets (SYNDOPA) were found to be 101.98 and 100.47 respectively for LD and CD. The proposed method was validated as per ICH guidelines and successfully applied for the simultaneous estimation of LD and CD in tablet formulations and dissolution sample analysis.