RP- HPLC Method for Simultaneous Estimation of Paracetamol and Etoricoxib from Bulk and Tablets

 

By S. R. Pattan, S. G. Jamdar, R. K. Godge, N. S. Dighe, A.V. Daithankar, S. A. Nirmal and M.G.Pai

 

Abstract

A simple, selective, rapid, precise and economical reverse phase high-pressure liquid chromatographic method has been developed for the simultaneous estimation of Paracetamol and Etoricoxib from pharmaceutical formulation. The method was carried out on an inertsil ODS, 5µ , C8-3 column, with a mobile phase consisting of methanol: acetonitrile: phosphate buffer pH 3.5 (40:20:40 v/v) at a flow rate of 1.0 ml/min. Detection was carried out at 242. The retention time of Paracetamol and Etoricoxib were 3.27, 6.12 min. respectively. The developed method was validated in terms of accuracy, precision, linearity, Limit of detection, Limit of quantitation.The proposed method can be used for estimation of these drugs in combined dosage form for routine analysis.

Key Words: Paracetamol, Etoricoxib, RP-HPLC.

 

download complete article in pdf format

 

 

 

 

Bookmark and Share